Chromate-free water-based epoxy primer two component.
P65-C2K primer is used on composite structures to guarantee their protection.
Coatings for Aircraft Structure Protection
Specifications
Brands |
N/A AkzoNobel |
Specifications |
N/A
Qualified in accordance with: |
Surface Conditions
Surface Preparation |
N/A
P65-C2K primer can be applied directly on composite parts, suitably degreased and sanded. |
Physical Properties
Theoretical Coverage for 20 Microns (µm) (0.8 Mils) Dry |
N/A 20 m²/L815 ft²/gal |
Dry Film Weight |
N/A 1.5 g/m² |
Volatile Organic Compounds (VOC) Volume as Per International Organization for Standardization (ISO 11890-1) |
N/A 130 g/L |
Volatile Organic Compounds (VOC) Volume as Per American Society for Testing and Materials (ASTM D 3960) |
N/A 250 g/L |
Color |
N/A Beige RAL1001 |
Shelf Life/Storage |
N/A 12 months for the base and hardener, stored between 5ºC and 35ºC (41ºF and 95ºF) in full and sealed original packaging. |
Gloss Level |
N/A 80 GU at 60º |
Note |
N/A
Gloss levels have been determined using glossmeter with an angle of incidence of 60º. The theorical consumption value doesn’t take into account the transfer efficiency for spray application |
Instructions for Use
Instructions for Use (Spray Application) |
N/A
Mixing ratio by weight - Base 100 |
Instructions for Use (Brush Application) |
N/A
Mixing ratio by weight - Base 100 |
Application Recommendations
Temperature Condition |
N/A 15 to 35 ºC60 to 95 ºF |
Relative Humidity Condition |
N/A 20 to 85 % |
Equipment |
N/A Gravity compressed air gun Nozzle 1 mm to 1.8 mm |
Dry Film Thickness |
N/A 15 to 25 µm0.6 to 1 mil |
Wet Film Thickness |
N/A 20 to 45 µm0.8 to 1.8 mil |
Equipment Cleaning |
N/A
Clean the equipment with a suitable cleaning solvent such as Mapaero D760. Mapaero D770-B aqueous cleaning solvent can also be used. |
Number of Coats |
N/A
Apply 1 crossed coat to achieve a 15 µm to 25 µm (0.6 to 1 mil) dry thickness. Each coat has to be wet and of the same thickness. |
Note for Application Recommendations |
N/A Spray with dry, oil-free air. |
Dry Time
Dry to Handle Drying Time at 23 Degree Celsius (ºC) (73 Degree Fahrenheit (ºF)) Temperature |
N/A 5 hour |
Dry to Handle Drying Time at 60 Degree Celsius (ºC) (140 Degree Fahrenheit (ºF)) Temperature |
N/A 45 minutes |
Dry to Handle Drying Time at 80 Degree Celsius (ºC) (176 Degree Fahrenheit (ºF)) Temperature |
N/A 10 minutes |
Dry to Tape Drying Time at 23 Degree Celsius (ºC) (73 Degree Fahrenheit (ºF)) Temperature |
N/A 6 hour |
Dry to Tape Drying Time at 60 Degree Celsius (ºC) (140 Degree Fahrenheit (ºF)) Temperature |
N/A 50 minutes |
Dry to Tape Drying Time at 80 Degree Celsius (ºC) (176 Degree Fahrenheit (ºF)) Temperature |
N/A 15 minutes |
Recoatable Drying Time at 23 Degree Celsius (ºC) (73 Degree Fahrenheit (ºF)) Temperature |
N/A 10 minutes to 3 days |
Recoatable Drying Time at 60 Degree Celsius (ºC) (140 Degree Fahrenheit (ºF)) Temperature |
N/A 10 minutes to 2 hours |
Recoatable Drying Time at 80 Degree Celsius (ºC) (176 Degree Fahrenheit (ºF)) Temperature |
N/A 5 minutes to 35 minutes |
Fully Cured Drying Time at 23 Degree Celsius (ºC) (73 Degree Fahrenheit (ºF)) Temperature |
N/A 3 days |
Fully Cured Dry Time at 60 Degree Celsius (ºC) (140 Degree Fahrenheit (ºF)) Temperature |
N/A 2 hours 30 |
Fully Cured Dry Time at 80 Degree Celsius (ºC) (176 Degree Fahrenheit (ºF)) Temperature |
N/A 1 hour |
Note for Drying Times |
N/A
Drying times have been determined using test pieces of 1 mm thickness, with a 20 µm (0.8 mils) dry film. |
Defects and Corrections
Defects and Corrections |
N/A
In the event of a defect, contact your Quality Department. |
Warranty
Warranty |
N/A
We guarantee our products against hidden defaults over material and preparation. Our Responsibility is limited to the obligation of freely replacing the defective material without there being a claim for any compensation. The advice we give is based on our experience but it might not be absolutely right. Consequently this does not imply our responsibility in case of inefficiency. Furthermore our company cannot be responsible for any material or corporal damages caused due to a misuse or mishandling of our products. Any concession to these clauses, to be valid, must be an official document issued by our offices and signed by our direction. |